CANOGA PERKINS L351 10/100BASE Media Converter User Manual
Page 43
EdgeAccess Universal Chassis System
L351 10/100BASE Media Converter
4-24
To upgrade a remote unit to the same version of software, follow these steps:
1. From the Main Menu, type
7
, "Software Upgrade," and press <Enter>.
2. At the Software Upgrade menu, type
3
, "Copy Software from Source unit to Destination unit,"
and press <Enter>.
3. At the prompt, select the Source, which is the inactive bank for the local module, then select the
Destination, which is the inactive bank for the remote module, and press <Enter>; the upgrade
runs automatically.
To run the new software, swap banks, and reset the module, follow these steps:
1. From the Main Menu, type
7
, "Software Upgrade," and press <Enter>.
2. At the Software Upgrade menu, type
2
, "Swap Bank," press <Tab> to highlight the Remote
column, and press <Enter>.
3. Type
2
, "Swap Bank," check that the Local column is highlighted, and press <Enter>. Both
modules reset and start using the new firmware.