Ethernet Termination Service Unit
Figure 5 – Bracket Attachment Detail
b. Wall mounting: The N525 has slotted holes on the bottom of the unit for wall
mounting. The N525 requires 1” unobstructed space above and below the N525
for ventilation. Canoga Perkins recommends a space of 5” on the right and 3” on
the left of N525 bee left unobstructed to facilitate Interface Module Access, Cable
Access and Power Entry.
• Install two #10 or #12 screws and anchors in the wall 9 3/8” apart, 1” from the
sides and 3/4” from the top of the desired location of the N525. A template is
illustrated below. Leave the screws protruding from the wall 3/8” to 3/4”.
• Hang the N525 on the screws, matching the keyholes in the N525 to the screws.
Figure 6 – Wall-Mount Template