Setting up snmp network management, Network management platform set-up, N525 set-up – CANOGA PERKINS N525 Ethernet Termination Service Unit User Manual

Page 20

Advertising
background image

3-2

N525 Ethernet Termination Service Unit

Setting Up SNMP Network Management

Typically, the N525 communicates with CanogaView or your Network Management
Platform in-band via the transported Ethernet Network.

Network Management Platform Set-up

Industry standard Management Information Bases (MIBs) are required on your Network
Management Platform in order to successfully communication with the N525 using
SNMP. Before you start, check that these industry-standard MIBs are loaded:

1. Standard MIB
2. Dot2sd.mib
3. Etherlike.mib
4. If.mib
5. Bridge.mib
6. Pbridge.mib

Additionally, Canoga Perkins Private MIBs are need on the Management Platform. The
Canoga Perkins Private MIBs are available on Canoga Perkins web site,

www.canoga.com

. The MIBs are located in a password protected area of the Web Site.

If you do not yet have a Canoga Perkins Username and Password, please contact Tech
Support.

1. Cp.mib: Supports all Canoga Perkins products
2. Cpsysinf.mib: Supports SNMP access
3. Cphost.mib: Supports Host Table and Host Access functions
4. Cptraptb.mib: Supports the Trap Table

N525 Set-up

There are several TCP/IP and SNMP parameters that need configuration before
accessing the N525 from CanogaView or your Management Platform. These
parameters include TCP/IP Address, Authorized Host list and privileges. These
parameters are initially using VT-100 Terminal on the RS-232 Serial Port. Please see
the System Configuration section for details on configuring these parameters.