Switching on, Trouble-shooting, Trouble 12 – Leica Geosystems RCS1100 Series User Manual

Page 12: Switching on trouble-shooting

Advertising
background image

12

Preparation, Setting up

RCS1100-1.2.0en

After all connections and settings
have been inspected, the RCS1100
can be switched on. This
automatically brings the TPS1100
into the RCS mode. After a few
seconds, the display of the TPS1100
appears on the RCS1100.

Switching on

Trouble-shooting

Error

Cause / remedy

No data transfer when
starting up (short
distance between

TCPS26 and RCS1100)

Case 1 - Green LED on TCPS26 does not shine:
Inspect battery charge, and cables for TCPS26
Case 2 - Message "No signal" on RCS1100:
Inspect battery charge in RCS1100
or possible link numbers for RCS1100 and

TCPS26 are not the same.

Case 3 - Green LED shines and message appears
on RCS1100: Set interface paarmeters correctly on

TPS and TCPS26.

Data transfer possible,
but transmission fault

Case 1 - Red LED on TCPS26 flashes: Inspect
interface parameters.
Case 2 - Red LED on TCPS26 does not flash:
Connecting cable is defective

Data transfer is very
slow

Disturbance from other transmitters in the 2.4 Ghz

frequency band: Change link number in RSC1100

and TCPS26.

Interruption during data

transfer

Message "No signal" on RCS1100:Operation is at

the limit of the range, or there is no visual

communication between RCS1100 and TCPS26.
Establish visual communication, reduce distance,
use antenna extension.