Operation

6

7

8

15

Local functions, continued

Configure Modem / TCPS26

Disturbances to the radio link can be
improved by changing the link
number, which must then be altered
in the internal radio module and at
the same time in the TCPS26.

1. Connect the TCPS26 with a

Y-cable to the serial interface of
the RCS1100 and to the external
battery.

2. Switch on the RCS1100.
3. Press the

key for more than

two seconds to display the
configuration dialogue.

4. Pull out the plug of the TCPS26

and plug it back in to switch on the
TCPS26.

Serial Interface

Set the parameters in accordance
with requirements.

The standard parameters for the
TCPS26 are:

Baud

19200

Data bits

8

Parity

none

To ensure the correct
transfer of data, the settings

on the TPS1100 and on the
RCS1100 must be the same.

SERIAL INTERFACE

Set parameters:

Baud rate

:

19200

Parity

:

NONE

Terminator

:

CR/LF

Data bits

:

8

Stop bit

:

1

CONT

MC

Sleep:

Switches the TPS1000
to the sleep mode.

Applications which involve
the automatic repetition of

measurements may be interrupted if
the instrument is switched to the
sleep mode.

If a TPS1000 instrument is
connected, these functions

are not available.

Advertising