Analogue solutions, Sh-nz - sample+hold / noise – Analogue Solutions Concussor User Manual

Page 39

Advertising
background image

ANALOGUE SOLUTIONS

CONCUSSOR

e&oe (c) 12-2007

39

SH-NZ - Sample+Hold / Noise

Inputs:

Outputs: Power:

SH

Signal

SH

Signal

+/-12V

SH

Clock

Noise

Controls: Size:
SH

Slew

rate

6HP

Noise Level

Introduction

2 modules in one:

Sample and Hold and Noise features
The S+H and Noise units are in de pen dent so can be used en tire ly of each other.

Controls

S+H Slew

This adds slew (or portamento) between each changing voltage held by the S+H. So
as each voltage is sampled, the changes in old to new voltage level will be smoothed
out.

Noise Level

Alters the noise level.

Sockets

S+H In

This is the signal source for the S+H. Normally the noise output would be used for a random output.

S+H Clock In

Each clock or gate pulse will make the S+H sample the input signal then hold it till the next clock signal.
Normally a square wave signal would be fed into here, like the LFO-NZ square wave output.

S+H Sig Out

This is the output from the S+H unit.

Noise Out

This is an audio output from the white noise generator. This can be fed into the S+H signal input for random
S+H.

Obtaining a stepped random signal (using the Sample and Hold Facility)

To create a stepped random voltage (as indicated on the first position of the LFO wavform switch):
Patch a Square wave LFO output into the S+H Clock input, the Noise output to the S+H Signal input. Turn the Noise

level up to about 30-50% (A higher setting causes strange - though not neccessarily - output). The S+H output signal
will appear at the S+H Out socket.