Aviom A-16R/A-16CS User Manual

Page 16

Advertising
background image

7

A-16R P

eRsonAl

M

ixeR

And

A-16Cs C

ontRol

s

uRfACe

u

seR

G

uide

AN-16/i Input Module

AN-16/o Output Modules

or Personal Mixers

Up to 500 feet of Cat-5e

cable can be used to

connect each system

component

Infinite number

of A‑Net

components

Your cable length performance will be affected by a number of factors

including the quality of the cables used, and the number of devices such as

cable couplers used or passive wall panel interconnections in use. Use Cat‑5e

cable for best performance wherever possible. Stranded or solid Cat‑5e cable

can be used.

When using the optional AN‑16SBR System Bridge, the cable length

specification applies to the total cable length between the two A‑Net devices

being connected with the AN‑16SBR System Bridge. This is similar to what

happens when using an inline coupler to extend cable lengths.

Pro16 Input

Pro16 Output

Total A-Net cable length can be 500 feet (150 meters)

System

Bridge

A-Net Out

A-Net In

System

Bridge

Total cable length calculations include cables used top connect I/O modules

to System Bridges.

Pre‑made cables in a variety of lengths and colors are available at most

Advertising