Exit midi sysex mode – Aviom A-16R/A-16CS User Manual

Page 63

Advertising
background image

54

A-16R P

eRsonAl

M

ixeR

And

A-16Cs C

ontRol

s

uRfACe

u

seR

G

uide

The A‑16R will remain in MIDI Recall until a valid A‑16R MIDI message is

received, or until another front panel button is pressed to exit MIDI mode.

MIDI SysEx information for other manufacturer’s devices will pass through

the A‑16R and be ignored.

To load an All Preset data file via SysEx:

Set the A‑16R front panel

1.

R

emote

/l

ocal

switch to the l

ocal

position.
Press the

2.

R

ecall

button. The R

ecall

button LED flashes.

Press the

3.

S

olo

button to arm the A‑16R for MIDI reception.

The LED in the S

olo

button will blink.

Send the All Preset SysEx data file from your

4.

MIDI storage

device.
The sixteen Presets are loaded into the A‑16R internal

5.

memory sequentially.
The Mute LEDs will serve as a progress bar. The LEDs

6.

will light in order from 1 to 16 as each Preset is received

successfully.

When the All Preset SysEx file transfer is complete, the system will display a

status message to confirm that the data was received properly. Two messages

are possible:

• Valid Data Received ‑ all yellow Mute LEDs will flash

Invalid Data or

MIDI Error ‑ all red Channel LEDs will flash

Press any A‑16R button to acknowledge the transfer status message and

return the A‑16R to normal operation.

Exit MIDI SysEx Mode

You can exit an All Preset SysEx load operation by pressing any A‑16R front

panel button, or by changing the position of the Remote/Local switch.

Presets that have been successfully received prior to exiting the SysEx recall

mode will be preserved in the internal memory of the A‑16R. The remaining

internal Preset memory of the A‑16R will remain unchanged.

Advertising