Sample rates and a‑net slots, Channel activation button, Sample rates and a-net slots – Aviom 6416i User Manual

Page 47

Advertising
background image

20

F

roNt

P

ANel

F

eAtures

confirmation is required. To confirm the new sample rate, press the

E

ntEr

button. To exit without changing the sample rate, press

C

anCEl

.

Pressing the selection

button will cycle through the

available sample rates.

Attempting to change the sample rate on a module that is not the Clock

Master will cause the Sample Rate and Clock Master LEDs to flash to indicate

the error.

Sample Rates and A-Net Slots

Changing the network sample rate has a direct effect on the availability of

A‑Net Slots. For example, setting the sample rate to 96kHz makes only 32

Slots available, numbers 1 through 32. Slot numbers 33‑64 are no longer

available.

If at the 48kHz sample rate an input module such as the 6416i is set to the

Slot range starting at 33 or 49 and has active channels, these channels will be

deactivated when the sample rate changes to 96kHz. These Slot assignments

no longer exist in the network.

Channel Activation Button

Each of the sixteen line‑level input channels on the 6416i can be made active

on the network individually using the lighted Active button found below

the gain range switch on each channel. Activating a channel assigns it to an

A‑Net Slot, making it part of the network and available to any output module

in the network.