Digital copies in manual mode – Aviom 6416i User Manual

Page 81

Advertising
background image

17

b

uildiNg

A

P

ro

64 N

etwork

Digital Copies in Manual Mode

Creating a digital split in Manual Mode follows most of the rules defined for

Auto Mode splits. Any output modules connected in series to an existing

output module can output the same audio as long as the A‑Net Slot range

and A‑Net Receive Port settings are configured properly, and as long as no

input modules installed overwrite the audio. However, the location of the

Pro64 output modules used for the splits will impact the front‑panel transmit

port settings of the input modules.

Example 8: Adding a digital split of the FOH signals

B A

B A

Input

B A

Output

B A

Input

B A

Output

B A

Input

B A

Input

B A

Output

1 2

Merger

3 4 5 6 7 8 9 10

B A

B A

Input

B A

Output

B A

Input

B A

Output

B A

Input

B A

Input

B A

Output

1 2

Merger

3 4 5 6 7 8 9 10

B A

B A

Input

B A

Output

B A

Input

B A

Output

B A

Input

B A

Input

B A

Output

1 2

Merger

3 4 5 6 7 8 9 10

B A

B A

Input

B A

Output

B A

Input

B A

Output

B A

Input

B A

Input

B A

Output

1 2

Merger

3 4 5 6 7 8 9 10

STAGE

FRONT OF HOUSE

RECORDING

B A

B A

Input

B A

Output

B A

Input

B A

Output

B A

Input

B A

Input

B A

Output

1 2

Merger

3 4 5 6 7 8 9 10

The input module at FOH transmits its audio data out of both A-Net ports,

providing a digital split.

Advertising