Control master dip switch – Aviom 6416i User Manual

Page 72

Advertising
background image

36

v

irtuAl

d

AtA

c

Ables

The following table lists the DIP switch settings for the available RS‑232 baud

rates.

Switch

Baud Rate

1

2

3

4

1200

off

off

off

off

2400

off

off

off

on

4800

off

off

on

off

7200

off

off

on

on

9600

off

on

off

off

14400

off

on

off

on

19200

off

on

on

off

28800

off

on

on

on

38400

on

off

off

off

57600

on

off

off

on

31250 (MIDI)

on

off

on

off

Control Master DIP Switch

In the RS‑232 DIP switch block on the 6416i, switch #10 is used to set the

module as the network’s Control Master. Only one module can be designated

as Control Master in a Pro64 network.

When switch #10 is in the up position, the 6416i becomes the network’s

Control Master. (Black indicates the DIP switch handle.)

To set the 6416i as the Control Master, start with Pro64 network devices

powered off. Set switch #10 to the up position. Power up the 6416i and the

rest of the network devices. The red Control Master LED on the front panel of

the 6416i should be lit indicating that it is now the network’s Control Master.

N

ote

: Be sure that only one Pro64 device is set to be the network Control

Master.