Chapter III pan/tilt parameter setting

Prior to install this product, please firstly confirm the communication protocol and baud

rate of system control host, then set the SW2DIP switch of pan/tilt according to that of

system, including SW1 setting of pan/tilt address, SW2 setting of communication protocol

type and baud rate.

3.1 Setting of termination resistance

The JP1 jumper is the RS485 bus 120Ω termination resistance selecting switch. When it is

at 2—3 state,120Ω termination resistance is open, that is, no 485 bus terminated; when it

is under 1—2 state, 120Ω termination resistance is paralleled into 485 bus. In the whole

RS485 bus system, at most only one pan/tilt may connect the termination resistance into

circuit; all other pan/tilt shall let the termination resistance opening to increase the system

reliability. Usually the pan/tilt at the farthest end of control line may be connected, but the

termination resistances of all other equipment are opening.

4

1 2 3

5 6

10

7 8

6

5

3

2

OFF

2-3

ON

1-2

120R

JP1

3

2

1

2

3

JP

1

JP1

1

ON

1

4

9

ON

1 2 3 4 5 6

ON

7 8

9 10

4 5 6

1 2 3

ON

SW1 address setting DIP switch

Sw2 protocol selection

Fig.1

3.2 Setting of DIP address:

SW1 may set the pan/tilt address, with range 1~1023. From DIP-10 to DIP-1, it is

equivalent to a 10-bit binary number. DIP-10 is the highest bit; DIP-1 is the lowest bit.

The “ON” state of each bit indicates 1, and “OFF” indicates 0. The followings are the DIP

table of partial address code: