Hardy Floor Scales User Manual

Page 16

Advertising
background image

Hardy Floor Scales

7

FIG. 3 DIRECTION WHEN DRIVING HEAVY

EQUIPMENT ON AND OFF THE SCALE

FLOOR SCALE
INSTALLATION

Step 1.

Place the platform scale on the operating
location. Make sure that the platform
height is within 3 to 3.275" as measured
from the top of the cover plate to the top of
the floor surface. (See Fig. 4)

NOTE:

With the scale in place, the clearance around the edge
of the platform and pit coping should be 1/4” to 3/8”.

FIG. 4 MAXIMUM HEIGHT

Load and unload
heavy equipment
in this direction only!

3.275” (83.1mm)

Advertising