Hardy WS100 Configuration Software User Manual

Page 41

Advertising
background image

HI WS100 CONFIGURATION SOFTWARE

6-2

the instrument, HI WS100 automatically
loads the number of C2 load cells that
are incorporated in your weight system.
The number will automatically display
in the Number of Sensors field. Having
the HI 215IT Junction Box enables the
configuration software to list the test
results for each individual load cell in
your weighing system.

If you have non-C2 load cells and an Hi
215JT Junction Box, then you need to
add the number of load cells in your sys-
tem by clicking on the up or down
arrows or double clicking in the field
and typing the number, to enter the
number of load cells in your weight sys-
tem. Having the HI 215IT Junction Box
enables the configuration software to list
the test results for each individual load
cell in your weighing system.

If you do not have the HI 215IT Junc-
tion Box, the configuration software will
give you a combined test result of all the
load cells in your weighing system. (See
Fig. 6-1)

Step 3.

Click on the Test button. After a second or
two the results of the test will appear in the
fields. The tests are:

1.

Loadcell Impedance

Base R is the impedance at the
time of the last Calibration.

Read R is the impedance reported
during the test.

Test R indicates whether the cell
is good or bad.

NOTE:

Keep in mind that if you have the HI 215IT Junction
Box the Test R result will appear for each load cell.
Therefore you will know exactly which load cell
failed. If you do not have an HI 215IT Junction it will

Advertising