Technical data – Holtgreven Ohaus Defender Series Bench Scales User Manual

Page 57

Advertising
background image

EN-55

5000 Series Indicators

8. TECHNICAL DATA

8.1 Specifications

Materials
T51XW Housing: stainless-steel
T51P Housing: ABS plastic
Display window: polycarbonate
Keypad: polyester
Feet: Rubber

Ambient conditions
The technical data is valid under the following ambient conditions:
Ambient temperature: -10°C to 40°C / 14°F to 104°F
Relative humidity: Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50%
relative humidity at 40°C.
Height above sea level: up to 2000m
Operability is assured at ambient temperatures between -10°C and 40°C.

Indicator

T51P

T51XW

Maximum Displayed Resolution

1:30,000

Maximum Approved Resolution

1:10,000

Maximum Counting Resolution

1:300,000

Weighing Units

kg, lb, g, oz, lb:oz, tonnes, custom

Functions

Static Weighing, Dynamic Weighing, Counting, Checkweighing, Percent Weighing

Display

25 mm / 1 in High 6-digit, 7-segment LCD

Over/Accept/Under Indicators

Red, Green, Yellow LED

Backlight

White LED

Keypad

4-button membrane switch

Ingress Protection

---

IP66

Load Cell Excitation Voltage

5V DC

Load Cell Drive

Up to 8 x 350 ohm Load Cells

Load Cell Input Sensitivity

Up to 3 mV/V

Stabilization Time

Within 2 Seconds

Auto-zero Tracking

Off, 0.5, 1 or 3 Divisions

Zeroing Range

2% or 100% of Capacity

Span Calibration

1 kg or 1 lb to 100% Capacity

Housing Dimensions (W x D x H)
(mm/in)

260 x 71 X 168 / 10.2 x 2.7 x 6.6

262 x 76 x 149 / 10.3 x 3.0 x 5.8

Net Weight (kg/lb)

1.5 / 3.3

3.5 / 7.7

Shipping Weight (kg/lb)

2.3 / 5

4.3 / 9.5

Operating Temperature Range

-10°C to 40°C/14°F to 104°F

Power

100-240 VAC / 50-60 Hz Internal Universal Power Supply,

6 C-type batteries (T51P)

Interface

Built-in RS232 and External Input

TABLE 8-1. SPECIFICATIONS

Advertising