Industrial Data Systems IDS 440 User Manual

Page 12

Advertising
background image

IDS440 Users Manual version 4.2

Installation and Setup

8

Setup Guide

Setup the IDS440 in the following order:

Initialize to Factory Defaults

The IDS440 is initialized at the factory. It must be re-initialized if the program memory

(EPROM) or the parameter memory (EAROM) is replaced. The Initialize function

clears the memory and sets the configuration parameters to their default values. Use

parameter function 70 described in

Parameter Functions to initialize the IDS440.

NOTE: Calibration and setup must be performed after the IDS440 is initialized.

Setup & "Quick" Calibration Guide

The IDS440 should be configured BEFORE calibration.

Set Operation Parameters

details all of the scale parameters that are available. To quickly get the IDS440 up and

running, the following Quick Calibration Guide lists only the mandatory parameters that

must be defined. Enter the following scale parameters using the selection outlined in

Set

Operation Parameters and Parameter Functions.

Parameter (section)

Purpose (Factory Setting)

1 (Set Operation Parameters)

Load Cell mv/V (3)

11 (Set Operation Parameters)

Decimal Point (none)

12 (Set Operation Parameters)

Count-by (1)

17 (Set Operation Parameters)

Full Scale Graduations (10,000)

18 (Set Operation Parameters)

Overload Graduations (10,200)

60 (Parameter Functions)

Calibrate Scale


Calibrate the Weight Indicator

Use Parameter Function 60 to calibrate the weight indicator (page 6-3).

Advertising