60

IDS440 Specifications

Display

1 inch x 6-digit numeric, 6 LED status indicators.

Keyboard

Sealed keyboard with tactile feel.

I/O Ports

Load Cell Interface Port.

Serial port 1 - RS232 or Cur. Loop.

Serial port 2 - RS232 or RS485.

9 TTL outputs.

8 TTL inputs.

Display Graduations 120,000 graduations (industrial)

10,000 hb44.

Display Increments 1, x2, x5, x10, x20, x50, x100.

Decimal Point

0 to 4 decimal places.

Internal Graduations 1,024,000.

Conversion Rate

60/sec @60hz line frequency (HS version 100/sec @ 60hz)

Signal Sensitivity

0.1 uV/graduation (min).

Signal Range

0.5 mV/V - 3.9 mV/V.

Load Cell Excitation 10 VDC.

Load Cell Current

240ma (8, 350 ohm Load Cells).

Auto Zero Tracking 0 to 60 grads, @1/4 grad increments.

Auto Zero Delay

0 to 25 sec, @0.1 sec increments.

Motion Detect

0 to 60 grads, @1/4 grad increments.

Motion Delay

0 to 25 sec, @0.1 sec increments.

Digital Filter

19 settings (0 to 18).

Digital Calibration

Front Panel - zero & span stored in EAROM.

Watchdog Timer

Fault tolerant operation (212ms).

Power Input

115/220 VAC 50/60 Hz. Only the 115VAC.

Version has been tested to comply with the

Underwriters Laboratories Standards for safety.

Operating Temperature

-10 to 40 degrees centigrade.

Options

Counting.

Opto-22 relay modules.

12 to 28 volt DC operation.

220 VAC operation.

440HS High speed 100 samples a second.

Analog output module.