Industrial Data Systems IDS 440 User Manual

Page 32

Advertising
background image

IDS440 Users Manual version 4.2

Set Operation Parameters

28

Parameter 15. Alternate Count-by (5)

Enter the alternate units count-by.

Parameter 16. Alt Units Conversion Factor (45,360)

The IDS440 calculates the alternate weight by multiplying the primary weight by the

conversion factor and then dividing by 100,000. The following table lists some common

conversions.

Alternate Units Conversion Factor Table

Conversion

Conversion Factor

Conv. Fact. x 100,000

lb to kg

0.45359 kg/lb

45,359

kg to lb

2.20462 lb/kg

220,462

lb to ton

0.0005 Ton/lb

50

kg to tonne

0.001 tonne/kg

100

gram to oz

0.352739 oz/gram

352,739

oz to gram

28.3495 gram/oz

2,834,950

lb to lb

kb to kg

Etc.

1

100,000

Enter the conversion factor x 100,000 for the configured alternate units.

Parameter 17. Full Scale Graduations (10,000)

Enter the number of graduations at full scale. The full-scale graduations are calculated

using the count-by, decimal position, and full-scale weight.

Full Scale Graduations = Full Scale Weight / count-by.

For example, if Full Scale Weight = 600.0 and count-by = 0.2 then Full Scale

Graduations = 600.0 / 0.2 = 3000.

Parameter 18. Overload Graduations (10,200)

Enter the number of graduations at which the scale is in overload status. The IDS440

displays Err oL on the numeric display when the scale weight exceeds overload. For

example, if the Full Scale Graduations is 10,000 grads and the scale is rated for 2%

overload, then Overload Graduations = 10,000 + (10,000 x 0.02) = 10,200.

Parameter 19. Deadload Offset

This parameter is automatically calculated by the configure function (60 & 80).

Parameter 20. Disable Power-On Zero (1 [disabled])

Enter a 1 to disable the power-on zero function. Enter a 0 to enable power-on zero. The

power-on zero function attempts to acquire zero when the power on tests have completed.

If the weight on the scale is above the zero range the display prompts “Err 0”. Press the

ENTER key to view the scale weight. Remove the weight from the scale to enter

weighing mode.