IDS440 Users Manual version 4.2

General Description

5

The IDS440 Display

The IDS440 DISPLAY consists of a 6 character NUMERIC display and 6 statuses LED’s

The NUMERIC display is normally used to display the weight on the scale. The LED’s

display the scale status. When lighted they indicate the following conditions:

GROSS-

The number displayed is the gross weight on the scale.

NET -

The number displayed is the net weight on the scale.

MOTION-

The weight on the scale is changing (not stable).

ZERO-

The scale is at "Center of Zero".

lb-

The weight displayed is in increments of pounds.

kg-

The weight displayed is in increments of kilograms.

The IDS440 Keyboard

The keyboard is used to initiate weighing functions and for data input and setup of the

IDS440. It is divided into 3 sections: Numeric Keypad, Function Keys, and Control keys

as shown on the previous page.

Numeric Keypad

The numeric keypad is used for numeric data entry. Alphanumeric entry is performed

using a three-digit code for every alphanumeric character. Some system parameters may

require alphanumeric entry. Instructions for alphanumeric entry are provided where

needed.

Function Keys

The function keys ZERO, TARE, GROSS/NET, UNITS and PRINT are used to perform

the functions of zeroing the scale, tarring the scale, switching the weight display between

gross and net display, switching the weight display between LB and KG display, and

printing the weight. The function keys F1 and F2 are programmable using Scale Basic

functions.

Control Keys

The control keys ENTER, and CLEAR are used to control the data entry operations for

ID’s, setpoints and setup.