3-5

Overview of PROFIBUS DP Communication

3-21

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -

Execu

ting Communi

cat
ion

3

Output

Functions assigned to the external input request 1 to 5 are as follows:

External input request 1: Zero shift input

External input request 2: TIMING input

External input request 3: RESET input

External input request 4: Standard waveform input

External input request 5: Laser emission stop input

Refer to the IG series user's manual.

Octet

Bit

Function name

Description

Value

0 to 4

0

External input request 1

Requests the external input to the
sensor amplifiers.

0: OFF
1: ON

1

External input request 2

Requests the external input to the
sensor amplifiers.

0: OFF
1: ON

2

External input request 3

Requests the external input to the
sensor amplifiers.

0: OFF
1: ON

3

External input request 4

Requests the external input to the
sensor amplifiers.

0: OFF
1: ON

4

External input request 5

Requests the external input to the
sensor amplifiers.

0: OFF
1: ON

5

Reserved for system

-

-

6

Reserved for system

-

-

7

Reserved for system

-

-