6 dp-v1 service, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual

Page 56

Advertising
background image

3-6

DP-V1 Service

3-34

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -

Execu

ting Communi

cat
ion

3

121

Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 1)

DINT

R/W

02

2 to 14

122

Specified edges interval
measurement mode: Edge
number 1 (BANK 2)

*19

DINT

R/W

+001

-100 to +100

123

Specified edges interval
measurement mode: Edge
number 2 (BANK 2)

*19

DINT

R/W

+002

-100 to +100

124

Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 2)

DINT

R/W

02

2 to 14

125

Specified edges interval
measurement mode: Edge
number 1 (BANK 3)

*19

DINT

R/W

+001

-100 to +100

126

Specified edges interval
measurement mode: Edge
number 2 (BANK 3)

*19

DINT

R/W

+002

-100 to +100

127

Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 3)

DINT

R/W

02

2 to 14

128

Group4 Entry count

DINT

R

31

129

Calculation function

DINT

R/W

0

0: Do not use calculation

function

1: Addition mode
2: Subtraction mode
3: 2-head mode

130

Measurement mode

DINT

R/W

0

0: Edge control/positioning mode
1: Outer diameter/width

measurement mode

2: Inner diameter/gap

measurement mode

3: Glass edge mode
4: Pin position measurement mode
5: Pin interval measurement mode
6: Pin diameter measurement mode
7: Specified edge interval

measurement mode

131

Measurement direction

DINT

R/W

0

0: Top
1: Bottom

132

Reserved for system

133

Averaging

*20

DINT

R/W

05

0:

hsp

1:

1 time

2:

2 times

3:

4 times

4:

8 times

5:

16 times

6:

32 times

7:

64 times

8:

128 times

9:

256 times

10: 512 times
11: 1024 times
12: 2048 times
13: 4096 times

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value

Advertising