Data update time

The data update time for cyclic communication is shown below.

Maximum data processing time = (1) + (2) + (3) + (4)
(1)PROFIBUS DP master data update time
(2)Network data update time
(3)Data update time between the DL-PD1 and sensor amplifiers

(4)Sensor amplifier response time

For (1) and (2), see manuals for each model.
For (4), refer to the User's Manual of each sensor amplifier connected to the DL-PD1.

Number of connected

sensor amplifiers

Control output/Comparator value

Calculation function

OFF

Calculation function

ON

1

7ms

7ms

2

12ms

12ms

3

14ms

14ms

4

18ms

18ms

(4)

(3)

(2)

(1)

DL-PD1

Sensor amplifier

PROFIBUS DP master