Communication methods, Channel-related diagnosis -15, Reading an output from a sensor amplifier – KEYENCE DL-PD1 User Manual

Page 45

Advertising
background image

3-5

Overview of PROFIBUS DP Communication

3-23

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -

Execu

ting Communi

cat
ion

3

Communication Methods

The following describes how the master cyclically communicates with the DL-PD1
(cyclic communication).

"Reading an output from a sensor amplifier" (page 3-23)

"Entering an external input to a sensor amplifier" (page 3-24)

"Reading comparator values (P.V. values) from sensor amplifiers" (page 3-25)

Reading an output from a sensor amplifier

Available outputs: High, Low, Go
This example shows how to read the High output from Slot 1 (ID01).

In the monitor mode

(1) The output from the sensor amplifier entered into Bit 0 of the input octet 2 via cyclic

communication. (In the big endian format)

This example shows how to read the High output from the sensor amplifier ID01.

In the I/O mode

(1) The output from the sensor amplifier entered into Bit 1 of the input octet 1 via cyclic

communication. (In the big endian format)

Output

High output of ID01

Sensor amplifier

Master

Sot 1

Bit 0 of the input octet 2

1

0

ON

OFF

(1)

Master

DL-PD1 (Sot 0)

Bit 1 of the input octet 1

Sensor amplifier

Output

High output of ID01

1

0

ON

OFF

(1)

Advertising