6 dp-v1 service, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual

Page 49

Advertising
background image

3-6

DP-V1 Service

3-27

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -

Execu

ting Communi

cat
ion

3

32

DL-PD1 error state

Stores the DL-PD1 error
status.

"Types of error and error

code" (page 4-3)

2byte

WORD

R

bit0-4: Error code
bit5-15: 0 (Fixed)

33

Number of connectable
units

Stores the number of sensor
amplifiers connected to the
DL-PD1.

2byte

INT

R

0 to 15

34 to 63 Reserved for system

64

Error state

When the sensor amplifier is
in the error state, the
corresponding bit is set.

"Types of error and error

code" (page 4-3)

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

65

Warning status

When the sensor amplifier is
in the warning state, the
corresponding bit is set.

"

Types of error and error

code" (page 4-3)

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

66

Comparator value property

When the sensor amplifier
comparator value is invalid or
exceeding the upper or lower
limit, the corresponding bit is
set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

67

Comparator value over
range

When the sensor amplifier
comparator value is
exceeding the upper limit, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

68

Comparator value under
range

When the sensor amplifier
comparator value is
exceeding the lower limit, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

69

Comparator value Invalid

When the edge output is ON,
the corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

70 to 77 Reserved for system

78

Output 1

When the control output of
sensor amplifier is High, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

79

Output 2

When the control output of
sensor amplifier is Low, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

80

Output 3

When the control output of
sensor amplifier is Go, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

81

Output 4

When the edge output is ON,
the corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

82 to 85 Reserved for system

Index

(DEC)

Function name

Description

Data

type

Attribute

Value