Entering an external input to a sensor amplifier, 5 overview of profibus dp communication, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual

Page 46

Advertising
background image

3-5

Overview of PROFIBUS DP Communication

3-24

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -

Execu

ting Communi

cat
ion

3

Entering an external input to a sensor amplifier

Available external inputs: PRESET, TIMING, RESET, error clear
This example shows how to enter the TIMING input from Slot 1 (ID01).

In the monitor mode

(1) The output octet value to which an external input request was assigned is linked via

cyclic communication and the external input of the sensor amplifier is turned on or
off. (In the big endian format)

(2) You can check the input status of the sensor amplifier with the external input response.

In the I/O mode

(1) The output octet value to which an external input request was assigned is linked via

cyclic communication and the external input of the sensor amplifier is turned on or
off. (In the big endian format)

(2)

(1)

Master

External input request

External input response

Sensor amplifier

External input

TIMING input of ID01

1
0

ON

OFF

1

0

Slot 1

Bit 1 of the output octet 0

Slot 1

Bit 1 of the input octet 2

Master

External input request

Sensor amplifier

External input

TIMING input of ID01

ON

OFF

1

0

DL-PD1 (Slot 0)

Bit 1 of the output octet 3

(1)