36

Judgment output / Edge
check output

*2

DINT

R

Bit0: HIGH judgment output
0: OFF, 1: ON
Bit1: LOW judgment output
0: OFF, 1: ON
Bit2: GO judgment output
0: OFF, 1: ON
Bit3: Edge check
0: OFF, 1: ON

37

Current value (P.V. value)

*3
*4

DINT

R

-99.999 to +99.999

38

Raw value (R.V. Value)

*3
*4

DINT

R

-99.999 to +99.999

39

Peak-hold value in hold mode

*3
*4
*5

DINT

R

-99.999 to +99.999

40

Bottom-hold value in hold
mode

DINT

R

-99.999 to +99.999

41

Calculation value (CALC
Value)

*3
*4
*6

DINT

R

-99.999 to +99.999

42

Analog output value

*7

DINT

R

Analog voltage output:
-5.000 to +5.000
Analog current output:
+04.00 to +20.00

43 to 44 Reserved for system

45

Number of edges

*8

DINT

R

0 to 99

46

Optical axis alignment state

DINT

R

0: Optical axis alignment NG

(optical axis alignment
indicator OFF)

1: Optical axis alignment OK

(optical axis alignment
indicator ON)

47 to 50 Reserved for system

51

Abnormal setting

*9

DINT

R

0: Normal setting
1: Abnormal setting

52

Reserved for system

53

EEPROM writing result

*10

DINT

R

0: Currently executing
1: Successfully completed
2: Writing failed

54

Zero shift/Zero shift reset
executing result

*11

DINT

R

0: Currently executing
1: Successfully completed
2: Unexecutable

55

Reset request result

DINT

R

0: Currently executing
1: Successfully completed
2: Unexecutable

56

System parameter current
state

*12

DINT

R

0 to 15