A&D Weighing AD-4407 User Manual

Page 26

Advertising
background image

Page

24

AD-4407 Weighing Indicator

Display and Other General Functions

Item

Parameter

Description

* 0

5 times/s

f04

Display update rate

1

10 times/s

The selection in the unstable
condition.

1 x

Key click (ON/OFF)

2 x

LoLo / Zero band

3 x

Lo

4 x

OK

5 x

HI

f05

[Type2]

Buzzer

6 x

HiHi /
Batch finish / Full

Left: Item, select using the

ZERO

key
Right: Parameter, select using

the

0

-

9

keys

0: no sound,

1: continuous

2: 4 times/s

3: 2 times/s

4: 1 time/s

5: 1 time/2a

Initial value is 11, others x0.

f06

Device ID(Address)

00 to

99

Command address
or DeviceID

Initial setting is 00.

* 0

Disable

f07

Counting function

1

Enable

*: Initial

settings. s:

second.

Key Switch

Item

Parameter

Description

10 11 CODE key
20 21 SAMPLE key
30 31 SETPOINT key
40 41 PT key
50 51 TOTAL key
60 61 M+ key
70 71 START key
80 81 STOP key
90 91 “9” key
a0 a1 MODE key
b0 b1 ZERO key
C0 C1 TARE key
d0 d1 NET/GROSS key
e0 e1 PRINT key

f12

[Type2]

Disabling of key
switch

f0 f1 ZERO+TARE = CAL

Left: Key
Right:

*

0 Enable

1 Disable

ZERO

key to select switch

0,

1

key to select

Enable/Disable


These options could be ignored
when Ff13 to f15 is set to 17
and shorting the terminal to the
common.

*: Initial

settings.

6.2. F-Functions

Advertising