background image

AD-4407 Weighing Indicator

Page

49

Request Net weight

Request Net weight

Request Net weight

Request Net weight

When receiving this command, returns the net data immediately.

Template

RN

Command

Reply

Request Tare weight

Request Tare weight

Request Tare weight

Request Tare weight

When receiving this command, returns the tare data immediately.

Template

RT

Command

Reply

Request Accumulated Data

Request Accumulated Data

Request Accumulated Data

Request Accumulated Data

When receiving this command, returns the accumulated data immediately.

Template

RA

Command

Reply

Refer Fixed data format of “8.1.2. Display and Operation, Output of

Accumulation data”.

Is Zero

Is Zero

Is Zero

Is Zero

When receiving this command, returns “at zero point” or no immediately.

Template

RZ

Command

Reply

when at ZERO

Not at ZERO

13.3.2.

Commands to Control the Indicator

Zero Display

Zero Display

Zero Display

Zero Display

Sets the current display to the zero point.

Template

MZ

Command

Reply

Tare

Tare

Tare

Tare

Sets the current display to zero of the net data.

Template

MT

Command

Reply

Clear Tare Data

Clear Tare Data

Clear Tare Data

Clear Tare Data

Clears the tare data and displays the gross data_.

Template

CT

Command

Reply

13.3. Command Format

Z

M

Z

M

T

M

T

M

T

C

T

C

Z

R

A

R

1

0

T

R

N

R

T

S

T

,

,

R

0

0

+

2

1

.

3

k

0

g

T

S

N

,

,

T

0

0

+

2

1

.

3

k

0

g

Advertising