This water heater shall not be connected to any heating systenns

or

component(s)

used

with

a

non-potable

water

heating

appliance.

All piping components connected to this unit for space heating

applications shall be suitable for use with potable water.

Toxic chemicals, such as those used for boiler treatment shall

not be introduced into this system.

Water supply systems may, because of such events as high

line pressure, frequent cut-offs or the effects of water hammer

among others, have installed devices such as pressure reducing

valves, check valves, back flow preventers, etc. to control these

types of problems. When these devices are not equipped with

an interna! by-pass, and no other measures are taken, the

devices cause the water system to be closed. As water Is heated,

it expands (thermal expansion) and closed systems do not allow

for the expansion of heated water.

The water within the water heater tank expands as it is heated

and increases the pressure of the water system.

If

the relieving

point of the water heater's temperature-pressure relief valve Is

reached,

the

valve

will

relieve

the

excess

pressure.

The

temperature-pressure

relief

valve

is

not

intended

for

the

constant relief of thermal expansion.

This is an unacceptable

condition and must be corrected. It is recommended that any

devices installed which could create a closed system have a

by-pass and/or the system have an expansion tank to relieve

the pressure built by thermal expansion in the water system.

Refer to the

Thermal Expansion section under Troubleshooting

Guide or contact local plumbing authority or local Sears Service

Center on how to control this situation.

NOTE: To protect against untimely corrosion of

hot

and cold

water

fittings,

it

is

strongly

recommended

that

di-electric

unions or couplings be installed on this water heater when

connected to copper pipe.

* •

CAUTION

Property Damage Hazard

• Avoid water heater damage.

• Install thermal expansion tank if necessary.

• Do not apply heat to cold water inlet.

• Contact qualified installer or Sears Service Center.

Figure 15 shows the typical attachment of the water piping to

the water heater. The water heater Is equipped with 3/4” NPT

water connections.

NOTE:

If using copper tubing, solder tubing to an adapter

before

attaching

the

adapter

to

the

cold

water

inlet

connection. Do not solder the cold water supply line directly

to the cold water inlet, it will harm the dip tube and damage

the tank.

• Look at the top cover of the water heater. The water outlet is

marked "HOT”. Put two or three turns of teflon tape around

the

threaded

end

of

the

threaded-to-sweat

coupling

and

around both ends of the 3/4” NPT threaded nipple. Using

flexible connectors, connect the hot water pipe to the hot

water outlet on the water heater.

Look at the top of the water heater. The cold water inlet Is

marked “COLD”. Put two or three turns of teflon tape around

the

threaded

end

of

the

threaded-to-sweat

coupling

and

around both ends of the 3/4” NPT threaded nipple. Using

flexible connectors, connect the cold water pipe to the cold

water inlet of the water heater.

NOTE:

This

water

heater

is

super

insulated

to

minimize

heat loss from the

tank.

Further reduction in heat loss

can

be

accomplished

by

insulating

the

hot

water

lines

from the water heater.

INSTALLATION COMPLETED USING INSTALLATION KIT

FLEXIBLE

WATER

CONNECTORS

T & P

Valve and Pipe Insulation

Remove insulation for T & P valve and pipe connections from

carton.

PIPE

INSULATION

FLUE PIPE

Fit pipe insulation over the incoming cold water line and the

hot water line. Make sure that the insulation is against the top

cover of the heater.

13