Gas piping, Wafer piping -13, Awarning – Kenmore 153.33443 User Manual

Page 16: Breathing hazard - carbon monoxide gas, Fire and explosion hazard

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

DRAFT HOOD

VENT TO OUTDOORS

OR CHIMNEY

FIGURE

17.

The vent pipe from the water heater must be no less than the

diameter of the draft hood outlet on the water heater and must

slope upward at least 1/4 inch per iinearfoot (21 mm per meter).

See Figure 18.

TO

CHIMNEY

Ali vent gases must be completely vented to the outdoors of the

structure (dwelling). Install only the draft hood provided with the

new water heater and no other draft hood,

Vent pipes must be secured at each joint with sheet metal screws.

There must be a minimum of 6 inches (153 mm) clearance

between single wall vent pipe and any combustible material.

Fill and seal any clearance between single wall vent pipe and

combustible

material

with

mortar

mix,

cement,

or

other

noncombustible substance. For other than single wall, follow

vent pipe manufacturer’s clearance specifications. To insure a

tight fit of the vent pipe in a brick chimney, seal around the vent

pipe with mortar mix cement.

AWARNING

Breathing Hazard - Carbon Monoxide Gas

Flue gases may escape if vent

pipe is not connected.

Do not store corrosive chemicals

in vicinity of water heater.

Chemical corrosion of flue and

vent system can cause serious

injury or death.

Contact

a qualified installer or

service agency.

Breathing carbon monoxide can cause brain damage

or death. Always read and understand instruction manual.

Be sure vent pipe is properly connected to prevent escape of

dangerous flue gases which could cause deadly asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur

if air for combustion contains certain chemical vapors. Spray

can

propellants,

cleaning

solvents,

refrigerator

and

air

conditioner refrigerants, swimming pool chemicals, calcium and

sodium

chloride,

waxes,

bleach

and

process

chemicals

are

typical compounds which are potentiaiiy corrosive.

Gas Piping

V

AWARNING

Fire and Explosion Hazard

• Do not use water heater with

any gas other than the gas
shown on the rating plate,

Excessive

pressure

to

gas

control valve can cause serious
injury or death.

Turn

off

gas

lines

during

installation.

Contact qualified installer or

service agency.

Failure to have required clearances between vent piping and

combustible material will result in a fire hazard.

Make sure the gas supplied is the same type listed on the model

rating

plate.

The

inlet

gas

pressure

must

not

exceed

14 inch water column (3.5kPa) for natural and propane gas (L.P.)

gas. The minimum inlet gas pressure listed on the rating plate

is for the purpose of input adjustment. If the gas control valve is

subjected to pressures exceeding 1/2 pound per square inch

(3.5kPa), the damage to the gas control valve could result in a

fire or explosion from leaking gas.

If the main gas line shutoff serving all gas appliances is used,

also turn “OFF" the gas at each appliance. Leave all gas

appliances

shut

"OFF”

until

the

water

heater

installation

is

complete.

A gas line of sufficient size must be run to the water heater.

Consult the current edition of National Fuel Gas Code ANSI

Z223.1/NFPA 54 and your gas supplier concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply

line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to

help prevent dirt and foreign materials from entering the gas

control valve.

A flexible gas connector or a ground joint union between the

shut off valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the

water heater. Use a soapy water solution, not a match or open

flame. Rinse off soapy solution and wipe dry.

The minimum inlet gas pressure shown on the rating plate is

that which will permit firing at the rated input.

16

Advertising
This manual is related to the following products:

153, 334, 530