Customer responsibilities, Product specifications – Kenmore 153.33443 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

CUSTOMER RESPONSIBILITIES

Thank You for

purchasing a Kenmore water heater. Properly

installed and maintained, it should give you years of trouble free

service. If you should decide that you want the new water heater

professionally installed by Sears call 1-800-4-MY-HOIVIE®. They

will arrange for prompt, quality installation by Sears authorized

contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

This

gas-fired

water

heater

is

design

certified

by

CSA

INTERNATIONAL

under

American

National

Standard/CSA

Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1

(current edition).

Read the “Safety Precautions” section, page 3 of this manual

first and then the entire manual carefully. If you don't follow

the safety rules, the water heater will not operate properly. It

could

cause

DEATH,

SERIOUS

BODILY

INJURY

AND/OR

PROPERTY DAMAGE.

This manual contains instructions for the installation, operation,

and maintenance of the gas-fired water heater. It also contains

warnings through out the manual that you must read and be

aware of. All warnings and all instructions are essential to the

proper operation of the water heater and your safety. Since

we cannot put everything on the first few pages,

READ THE

ENTIRE

MANUAL

BEFORE

ATTEMPTING

TO

INSTALL

OR

OPERATE THE WATER HEATER.

The installation must conform with these instructions and the

local code authority having jurisdiction. In the absence of

local codes, installations shall comply with the following:

The National Fuel Gas Code ANSI Z223.1/NFPA 54. This

publication

is

available

from

the

Canadian

Standards

Association, 8501 East Pleasant Valley Rd, Cleveland Ohio

44131,

or

The

National

Fire

Protection

Association,

1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not

understand any portion of the instructions, call the Sears

Service Center.

Carefully plan the place where you are going to put the water

heater.

Correct

combustion,

vent

action,

and

vent

pipe

installation

are

very

important

in

preventing

death

from

possible

carbon

monoxide

poisoning

and

fires.

See

figure 1.

Examine the location to ensure the water heater complies

with the

Facts to Consider About the Location section in this

manual.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an

earthquake.

See

instructions

for

correct

installation

procedures.

Instructions

may

be

obtained

from

your

local

dealer, wholesaler, public utilities or California Office of the

State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Oode requires this water heater to be installed

in

accordance

with

Massachusetts

248-CMR

2.00:

State

Plumbing Code and 248-CMR 5.00.

Complies

with

SCAQMD

rule

#1121

and

districts

having

equivalent NOx requirements.

PRODUCT SPECIFICATIONS

MODEL NUMBER

TANK

CAPACITY

IN GALS (LTRS)

TYPE

OF

GAS

INPUT

RATE

(Btu/hrj

RECOVERY

RATE

GALS.

PER

HOUR

@90°F

RISE

MINIMUM

VENT PIPE

INCHES

(mm)

DIAMETER

INCHES

(mm)

DIMENSIONS

IN INCHES

(mm)

HEIGHT TO

JACKET TOP

153.334430

40(151)

NATURAL

40,000

46.9

3” (76) or 4" (102)

20 1/2” (521)

55 1/2" (1,410)

153.334530

50(189)

NATURAL

40,000

45.8

3" (76) or 4" (102)

22” (558)

56 1/2" (1,435)

Advertising
This manual is related to the following products:

153, 334, 530