Warning, Operational, Condensation – Kenmore 153.33443 User Manual

Page 24: Smoke / odor, Conditions smelly odor, Air” in hot water faucets, High temperature shut off system, Explosion hazard

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

is not drawn toward the draft hood, shut off water heater and

make necessary air supply changes to correct.

Condensation

Whenever the water heater is filled with cold water, some

condensate will form while the burner is on. A water heater may

appear to be leaking when in fact the wafer is condensation.

This usually happens when:

• A new water heater is filled with cold water for the first time.

Burning

gas

produces

water

vapor

In

water

heaters,

particularly high efficiency models where flue temperatures

are lower.

Large amounts of hot water are used In a short time and the

refill water in the tank is very cold.

Moisture from the products of combustion condense on the

cooler tank surfaces and form drops of water which may fall

onto the burner or other hot surfaces to produce a “sizzling” or

“frying” noise.

Excessive condensation can cause pilot outage due to water

running down the flue tube onto the main burner and putting out

the pilot.

Because of the suddenness and amount of water, condensation

water may be diagnosed as a “tank leak”. After the water in the

tank

warms

up

(about

1

-2

hours),

the

condition

should

disappear.

Do not assume the water heater is leaking until there has been

enough time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The

water

heater

must

be

sized

properly

to

meet

the

family's

demands for hot water including dishwashers, washing machines

and shower heads.

Excessive condensation may be noticed during the winter and

early spring months when incoming water temperatures are at

their lowest.

Good venting is essential for a gas fired water heater to operate

properly as well as to carry away products of combustion and

water vapor.

Smoke / Odor

It is not uncommon to experience a small amount of smoke and

odor during the initial start-up. This is due to burning off of oil

from metal parts, and will disappear in a short while.

Operational

Conditions

Smelly Odor

In each water heater there is installed at least one anode rod

(see parts section) for corrosion protection of the tank. Certain

water conditions will cause a reaction between this rod and

the water. The most common complaint associated with the

anode rod is one of a “rotten egg smell”. This odor is derived

from hydrogen sulfide gas dissolved in the water. The smell is

the result of four factors which must all be present for the odor

to develop:

a concentration of sulfate in the supply water.

little or no dissolved oxygen in the water.

a sulfate reducing bacteria within the water heater. (This

harmless bacteria is non-toxic to humans.)

an excess of active hydrogen in the tank. This is caused by

the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater

models by replacing the anode(s) with one of less active material,

and then chlorinating the water heater tank and all hot water

lines. Contact Sears Service for further information concerning

an

Anode

Replacement

Kit

#9001453

and

this

Chlorination

Treatment. Anode replacement and chlorination of the tank are

not covered by the water heater’s limited warranty.

If the smelly water persists after the anode replacement and

chlorination treatment, it may be necessary to chlorinate or aerate

your water supply to eliminate the problem.

Do not remove the anode leaving the tank unprotected. By

doing so, all warranty on the water heater tank is voided.

“AIR” In Hot Water Faucets

A

warning

Explosion Hazard

Flammable

hydrogen

gases may be present.

Keep all ignition sources

away from faucet when

turning on hot water.

HYDROGEN GAS: Hydrogen gas can be produced in a hot

water system that has not been used for a long period of time

(generally

two weeks or more). Hydrogen gas is extremely

flammable and explosive. To prevent the possibility of injury

under these conditions, we recommend the hot water faucet,

located farthest away, be opened for several minutes before

any electrical appliances which are connected to the hot water

system are used (such as a dishwasher or washing machine).

If hydrogen gas is present, there will probably be an unusual

sound similar to air escaping through the pipe as the hot water

faucet is opened. There must be no smoking or open flame

near the faucet at the time it is open.

High Temperature Shut Off System

This water heater Is equipped with an automatic gas shutoff

system.

This

system

works

when

high

water

temperatures

are present. Turn “OFF” the entire gas supply to the water

heater.

The

high temperature shutoff is built into the gas

control

valve.

It

is

non-resettable.

If

the

high

temperature

shutoff

activates,

the

gas

control

valve

must

be

replaced.

Contact your gas supplier.