TROUBLESHOOTING GUIDE (Continued)

These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME® (1-800-469-4663)

for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.

Problem

Cause

Solution

WATER LEAKS

Improperly sealed, hot or cold supply

connection, relief valve, drain valve, or

thermostat threads.

Tighten threaded connections.

Leakage from other appliances or water

Inspect other appliances near water

lines.

heater.

Condensation of flue products.

Refer to CONDENSATION.

LEAKING T&P VALVE

Thermal expansion in closed water system.

Install thermal expansion tank (DO NOT

plug T&P valve).

Improperly seated valve.

Oheck relief valve for proper operation
(DO NOT plug T&P valve).

High sulfate or mineral content in water

Drain and flush heater thoroughly, then

SMELLY ODORS

supply.

refill.

Bacteria in water supply.

Chlorinate or aerate water supply.

Gas knob dial not positioned correctly.

Refer to LIGHTING INSTRUCTIONS.

Main gas supply off.

Turn on main gas shutoff valve.

Igniter tip more than 1/8” from pilot hood.

Adjust ignitor tip.

Thermopile malfunction.

Replace pilot assembly.

Thermopile TCO malfunction.

Replace pilot assembly.

Melted insulation on ignitor wire or shorting

Contact Sears Service to determine

PILOT WILL NOT LIGHT

of ignitor wire.

cause.

High ambient room temperature.

Contact Sears Service to determine

cause.

Wire disconnected from piezo igniter.

Reconnect wire connector to piezo igniter.

Broken electrode or electrical wire.

Replace pilot assembly.

Piezo Igniter generator fails to operate or

malfunctions.

Replace electronic control module.

Thermopile TCO malfunction.

Replace pilot assembly.

High ambient room temperature.

Contact Sears Service to determine

cause.

BURNER WILL NOT STAY LIT

Dirty or clogged Intake Screen.

Clean and reinstall Air Intake Screen.

Flame arrestor openings blocked.

Contact Sears Service to determine

cause.

Defective Gas Control.

Replace Gas Control.

Dirty pilot burner.

Clean pilot assembly.

Dirty or clogged Air Intake Screen.

Clean and reinstall Air Intake Screen.

PILOT OUTAGE

Thermopile malfunction.

Replace pilot assembly.

Thermopile TCO malfunction.

Replace pilot assembly.

Defective Gas Control.

Replace Gas Control.

Heater not lit or thermostat not on.

Refer to LIGHTING INSTRUCTIONS.

Thermostat set too low.

Refer to TEMPERATURE REGULATION,

Heater undersized.

Reduce hot water use.

NOT ENOUGH HOT WATER

Low gas pressure.

Contact your gas supplier.

Incoming water is unusually cold.

Allow more time for your heater to re-heat.

Leaking hot water pipes or fixtures.

Have plumber check and repair leaks.

High temperature limit switch activated.

Contact Sears Service to determine
cause.

WATER TOO HOT

Thermostat set too high.

Refer to TEMPERATURE REGULATION.

WATER HEATER SOUNDS

Condensation dripping on burner.

Refer to CONDENSATION.

SIZZLING-RUMBLING

Sediment or calcium in bottom or heater

tank.

Clean sediment from tank. Refer to
DRAINING instructions in Maintenance

section of manual.

SOOTING

Improper combustion.

No adjustment available. Contact Sears
Service to determine cause.

Lack of supply air.

VENT GAS ODORS

Improperly installed vent piping.

Contact Sears Service to determine

Downdraft.

cause.

Poor Combustion.