SECTION 5

SERVICE TECH. INFORMATION

5Â.

TROUBLESHOOTING

Keep this mainjal with yoiir water softener. If repairs are needed, the service technician must have
the information on the following pages. For telephone assistance, call toll free, 1-800-426-9345,

display

UP button

Sæs Water Iffîs

f o r C m l o m e r A s s i s l m c e

!-8i3iWiS-fl34S

0№QFF.

statARseTCMSKr

ON/OFF-HOID button
(Recharge TonIght-Now)

7

Demand Water Softener

SELECT button

r~

DOWN

button

ALWAYS MAKE THESE

INITIAL

CHECKS FIRST

1. Does the time display show the cotrect time of day?

-

If display is blank, check power soutce to the

softener.

“ If time is flashing, power was off for over 6 hours, The

softener resumes normal operation but regenerations
occur at the wrong time

- If an error code (Example: Err 03) shows in the face

place display, go

lo Automatic Electronic Diagnostics.

Z.

Plumbing bypass valve(s) must be In Full Service

position

3* The inlet and outlet pipes must connect to the softener

valve inlet and outlet respectively

4. Is the transformer plugged into a “live", grounded wail

outlet, and is the power cable fastened securely?

5. The valve drain hose must be free of kinks and sharp

bends, and not elevated over 8 ft above the floor

REMOVE THE TOP COVER AND SALT TANK COVER

6. Is there salt in the storage tank?

7. is the brine tubing connected? (See water flow

diagrams)

8

.

9.

Is the brine valve float set right? (See page 22)

Press the SELECT button 2 times to display the hardness

setting Be sure it is the correct setting for the
household’s water supply. (Make a hardness test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)

Press SELECT twice more to return the time of day

display.

If you do not Find the problem after making initial checks,
do the

Manual

Initiated Electronic Diagnostics, and the

Manual Advance Regeneration Check