SECTION 5

SERVICE TECH. INFORMATION

5Â.

TROUBLESHOOTING

CORRECT

SWITCH

DISPLAYS

VALVE CYCLE STATUS

Valve in service, fill, brining, back­
wash or fast rinse position

-_ pj

Valve rotating from one position to
another

While in this diagnostic screen, the following in­
formation is available and may be beneficial for
various reasons, This information is retained by
the computer from the first time electrical power

is applied to the face plate­
—' Press

0

to display the number of days this

face plate has had electrical power applied,

— Press Q to display the number of regenera­
tions initiated by this face plate since the SR code
number was entered.

2. Press the

button and hold 3 seconds un­

til.,.

SR 22 shows.

CODE

IpirjBig

This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will

operate on incorrect programming. Do the following
as needed.

Return the present time display: Press
SELECT button.

the

Change the

SR

number: To display the correct SR

number, press theQUP or DOWN Q burton. Press
SELECT, and

resei the timer.

NOTE:

If the face plate is left in a diagnostic display (or a flashing
display when setting times or hardness), present time
automatically returns if a button is not pressed within 4
minutes.

FACE

plate

; REPLACEMENT: Be sure the valve is in

service position (observe valve cycle indicator)
when replacing the face plate.

If, after installing and programming the replacement face

plate, the valve is not in service position, do the follow­
ing to assure correct cycle orientation, or timing, be­
tween the face plate and valve

Use the MANUAL ADVANCE procedures, page 22, With

the RECHARGE NOW button, advance through the re­
charge cycles until the valve stops in service position,
and RECHARGE no longer flashes in the timer,

NOTE; The valve motor may autamatically drive through
several valve positions while searching for service If an
enot code occurs, unplug the transformer, then plug in