SECTION

5

SERVICE TECH. INFORMATION

5Ä.

TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS

The face plate computei has a self-diagnostic

function for the electrical system (except input

power and water meter). The

computer monitors the electronic

components and circuits for cor-

Е,-

03

rect operation. If a malfunction occurs, an error code
appears in the face place display.

The chart below shows the error codes that could

appear, and the possible defects for each code

While an error code appears in the display, all face

plate buttons aie inoperable except the SELECT
button. The SELECT button remains operational so
the service person can make the Manual Initiated
Electronic Diagnostics to further isolate the defect,
and check the water meter,

CODE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

Err 01

motor inoperative / wiring harness or connection to switch / position switch / face plate

Err 02

face plate

Err 03

motor inoperative / face plate

Err 04

face plate / position switch

Err 05

face plate

PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE:

1 Unplug tiansformer 2 Correct defect 3 Plug-in

transformer 4. Wait for 6 minutes The error code will return if the defect was not corrected

MANUAL

INITIATED

ELECTRONIC

DIAG­

NOSTICS

1. To enter diagnostics, press and hold the SELECT

button until 000 — shows in the display.

TUHBINe SWiTCHES

UUU

WATER METER (AJ

1

SWITCH (B)

A. The first 3 digits indicate water meter operation

as follows:

.

000 (steady) -

Soft water not in use, and no

flow through the meter,

— OPEN A NEARBY SOFT WATER FAUCET—

000 to 199 (continual) =

Repeats display for

each gallon of water passing through the meter.

If you don't get a reading in the display, with the
faucet open, pull the sensor from the valve outlet

port. Pass a small magnet back and forth in front of
the sensor. You should get a reading in the display. If
you get a reading, unhook the

in

and

out

plumbing

and check the turbine for binding.

MOTOR

POSITION

SWITCH

B*

SENSOR

HOUSING

TURBINE

TURBINE

SUPPORT AND

SHAFT

VALVE

OUTLET

The letter (P) and dash (or dashes) indicate POSI­
TION switch operation. If the letter appears, the

switch is closed. If the dash shows, the switch is
open

Use the ON/OFF-HOLD (Recharge Now) button
to manually advance dte valve into each cycle
and check correct switch operation

20