SECTION 5

SERVICE TECH. INFORMATION

6A.

TROUBLESHOOTING

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve
motor, brine tank Fill, brine draw, regeneration flow
rates, and other controller functions. Always make
the ifiitial checks, and the manual initiated
diagnostics.

NOTE:

The face plate display must show a steady

time fnot flashing).

1. Press the ON/OFF-HOLD button and

hold in for

3 seconds.

RECHARGE NOW begins to flash as

the softener enters tlie fill cycle of regeneration
Remove the brinewell cover and, using a
flashlight, observe fill water entering the tank.

A. If it does not enter the tank, look for an ob­

structed nozzle, venturi, fill flow plug, brine tub­

ing, or brine valve riser pipe.

CYCLE FLOW RATES (GALLONS PER MIN.)

FILL (flow to salt storage tank)

0.3 (1.1 liters)

BRINING

\

.16 (.6 liters)

BRINE RINSE

I

.11 (.4 liters)

BACKWASH 1

1.8 (6.8 liters)

FAST RINSE )

1.8 (6.8 liters)

2. After observing fill, press the ON/OFF-HOLD

button to move the softener into brining. A slow
flow of water to the drain will begin. Verify brine
draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable
drop in the liquid level

NOTE:

Be sure a salt bridge is not preventing water

with salt contact

A. If the softener does not draw brine:

- nozzle and/or venturi dirty or defective.
- nozzle and venturi not seated properly on gas­
ket.
- restricted drain (check drain fitting and hose).
- defective nozzle and venturi seal.
- other inner valve defect (rotor seal, rotor &

disc, wave washer, etc)

NOTE:

If water system pressure is low, an elevated

drain hose may cause back pressure, stopping brine
draw

3. Again press ON/OFF-HOLD to move the soften­

er into backwash. Look for a fast flow of water

from the drain hose.

A. An obstructed flow indicates a plugged top dis­

tributor, backwash flow plug, or drain hose.

4. Press ON/OFF-HOLD to move the softener into

fast rinse. Again look for a fast drain flow. Allow
the softener to rinse for a few minutes to flush out
any brine that may remain in the resin tank from
the brining cycle test

5.

To return the softener to service, press ON/OFF-

HOLD.