Installation Instructions (cont’d)

Venting

A WARNING

To

insure

proper

venting

of

this

gas*fired

water

heater, the correct vent pipe diameter must be uti­
lized. Any additions of other gas appliances on vent

with this water heater will adversely affect the oper­
ation of the water heater.

The combustion and ventilation air flow must not be obstructed.

A WARNING

Chemical vapor corrosion of the flue and vent sys­
tem may occur if air for combustion contains certain

chemical v^ors. Spray can propellants, cleaning sol­

vents,

refrigerator

and

air

conditioner

refrigerants,

swimming pool chemicals, calcium and sodium chlo­

ride, waxes, bleach, and process chemicals are typi­
cal compounds which are potentially corrosive.

AWARNING

The power vent water heater requires its own (sepa­

rate) venting system. It cannot be connected to iui ex­
isting vent pipe or chimney. It must be terminated to

the outdoors. Failure to properly install the venting sys­
tem can result in asphyxiation, a fire or explosion and

can cause DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.

AWARNING

Obstructed

or

deteriorated

vent

systems

may

pre­

sent a serious health risk or asphyxiation.

Horizontal runs must be securely supported

at 3'A

foot intervals

and vertical runs supported at 5 foot intervals.

AWARNING

The

vent

pipe

from

the

water

heater

must

slope

upward 'A inch per five linear feet.

All vent gases must be completely vented to the outdoors of the

structure (dwelling).

AWARNING

Be sure vent pipe is properly connected to prevent

escape of dangerous flue gases which could cause
deadly asphyxiation.

VENTING THROUGH AN OUTSIDE WALL

ALL MODELS

3" PVC, ABS or CPVC Schedule 40 vent piping:

1. A3” PVC Schedule 40-45” vent cap with wire screen is sup­

plied with the water heater.

2. A 3" PVC, ABS or CPVC Schedule 40-90° street ell; used to

connect the vent pipe to the water heater when the vent pipe
is to be turned horizontally directly off the blower (supplied
locally).

3. 3" PVC, ABS or CPVC Schedule 40 pipe (must be supplied

locally).

3" PVC, ABS OR. CPVC

3" PVC, ABS OR CPVC

SCHEDULE 40 PIPE

VENT CAP

WITH

SCREEN

• The water heater requires its own (separate) venting system.

• 3” PVC, ABS or CPVC Schedule 40 piping and fittings are

acceptable materials for the vent system on all models.

• It cannot be connected to existing vent piping or chimney.

• It must terminate horizontally to the outdoors.