Installation instructions (cont’d), Gas piping (cont’d), A warning – Kenmore THE ECONOMIZER 153.33298 User Manual

Page 24: L. p)] gases, Sediment trap

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont’d)

Gas Piping (cont’d)

A WARNING

The appliance and its individual shutoff valve must

be disconnected from the gas supply piping sys­

tem during any pressure testing of the gas system
at test pressures in excess of 1/2 pound per square

inch {3.5kPa).

The appliance must be isolated from the gas sup­

ply piping system by closing its individual manual

shutoff valve during any pressure testing of the gas
supply

piping

system

at

test

pressures

equal

or

less than 1/2 pound per square inch (3.5kPa).

Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown.

GAS PIPING WITH

FLEXIBLE CONNECTOR

GAS SUr>PLY PIPING

MANUAL

SHUTOFF,

VALVE

A WARNING

Use pipe joint compound or teflon tape marked as
being resistant to the action of petroleum [Propane

(L. P)] gases-

SEDIMENT TRAP

A sediment trap shall be installed as close to the inlet of the

water heater as practical at the time of water heater installation.
The sediment trap shall be either a tee fitting with a capped nip­
ple in the bottom outlet or other device recognized as an effec­
tive sediment trap. If a tee fitting is used) it shall be installed in
conformance with one of the methods of installation shown.

GROUND JOINT

UNION

(OPTIONAL)

FLEXIBLE GAS CONNECTOR

LABELED AS COMPLYING

WITH ANSI STANDARDS

A

si

S

ud

T

DRIP LEG
(SEDIMENT

1 —0 o 5 У Т o'lsr i

3" MIN.

1

TRAP)

; CrojN ;

1

w

CAP

GAS

CONTROL

VALVE

A WARNING

Contaminants in the gas lines may cause improper
operation of the gas control valve that may result in
fire or explosion. Before attaching the gas line be
sure that all gas pipe is clean on the inside. To trap
any dirt or foreign material in the gas supply line, a
drip leg (sometimes called a sediment trap) must be

incorporated

in

the

piping.

The

drip

leg

must

be

readily accessible. Install in accordance with the "Gas
Piping” section. Refer to the current edition of the
National Fuel Gas Code, ANSI Z223.I, ^so referred

to as NFPA 54.

GAS PIPING WITH ALL BLACK IRON PIPE

TO GAS CONTROL

GAS SUPPLY PIPING

MANUAL

SHUTOFFj

VALVE

GAS

CONTROL

VALVE

24