Operating instructions (cont’d), Operating, A warning – Kenmore THE ECONOMIZER 153.33298 User Manual

Page 27: Operating instructions, Operating -28

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Operating Instructions (cont’d)

Operating

A WARNING

BEFORE

OPERATING

[PROPANE

(L.P.)

GAS

WATER

HEATERS]:

Propane

(L.P.)

gas

is

heavier

than ^r. Should there be a leak in the system, the gas
vfill settle near the ground. Basements, crav/l spaces,
skirted areas under mobile homes (even when venti­

lated), closets and areas below ground level will serve

as pockets for the accumulation of this gas. Before
attempting

to

operate

the

water

heater

or

turning

on a nearby electrical light switch, be absolutely sure
there is no accumulated gas in the area. Search for
odor of gas by sniffing at ground level in the vicinity
of the appliance. If odor is detected, follow steps indi­
cated at “For Your Safety’* on the cover page of this

manual then leave the premises.

Operating instructions are located on front of the water heater,
above or to one side of the gas control valve. See page 28.

A WARNING

AN ODORANT IS ADDED TO THE GAS USED

BY THIS WATER HEATER.

FOR YOUR SAFETY
IF YOU SMELL GAS:

• Do not try to light any appliance.
■ Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neigh­

bor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

4. The burner heats the water to the desired thermostat setting.

a) The resistance in the thermostat rises to the value

selected by the temperature control knob.

b) The control module closes the gas valve and 5 seconds

later, removes power from the blower.

5- Cycle is completed.

CONTROL SEQUENCE - HOT SURFACE DIRECT IGNITION

Pre-purge

5 sec.

HSI Warm-up

20 sec.

ignition Activation Period

4 sec.

Flame Recognition Period

Isec.

ignition Trial

4 sec.

interpurge

5 sec.

Post-purge

5 sec.

Retries

2

Reset from Lockout

1 hr.

Flame Sensing (Nominal)
HSI Off/Run Mode

4.0 pa DC

CHECK FOR LEAKS

Be sure to check all your gas pipes for leaks before operating
your water heater. Use a soapy water solution, not a match or
open flame. Check the factory gas fittings when the main burner
is turned “ON”.

WATER HEATING IGNITION SEQUENCE
(Make

sure

gas

and

electric

power

are

connected

properly)

1. The ignition control module is powered and monitors the sys­

tem, waiting for a call for heat from the thermostat.

2.

The thermostat calls for heat by reading a resistance value

within a given range directly proportional to water tempera­

ture.

3- The control module;

a) Checks the pressure switch for an open circuit.
b) Energizes the blower.
c) Checks the pressure switch for a closed circuit to prove

draft.

d) Sends line voltage to the hot surface igniter with a 20-

second warm up period.

e) Opens the gas valve and checks the sensing rod for

flame.

27