Installation Instructions (cont’d)

Venting (cont’d)

ALL MODELS — OPTIONAL 2" VENT PIPING

2" PVC, ABS or CPVC Schedule 40 vent piping:

1. A wire screen to fit a

2"

PVC, ABS or CPVC Scheduie 40­

45’’ vent cap is supplied with the water heater.

2. A 2" PVC, ABS or CPVC Schedule 40-45° vent cap (elbow)

(must be supplied locally).

3. A 3" PVC, ABS or CPVC Schedule 40 pipe, minimum

length of 3” (must be supplied locally), to make vent connec­
tion at the blower outlet.

4. A

3"

to 2" PVC, ABS or CPVC Scheduie 40 reducer (must

be supplied locally).

5. A 2" PVC, ABS or CPVC Schedule 40-90° street ell; used to

connect the vent pipe to the reducer when the vent pipe is to
be turned horizontally off the blower (supplied locally).

6. 2" PVC, ABS or CPVC Schedule 40 pipe (must be supplied

locally).

VENTING

SYSTEM

EXAMPLE

INSTALLATIONS

FOR ALL MODELS

The vent piping cannot under any circumstances be run down­
hill.

r

PVC, ABS OR. CPVC

SCHEDULE 40,.--n
90° ELBOW / M

2" PVC, ABS OR CPVC

SCHEDULE 40 PIPE

Horizontal runs require a minimum

Vs"

rise per five feet.

&

/ y \ r

r

TO 2" PVC, ABS OR

CPVC REDUCER

3" PVC. ABS OR CPVC

SCHEDULE 40 PIPE

(MINIMUM LENGTH 3")

VENT CAP

WITH SCREEN

• The water heater requires its own (separate) venting system.

• 2" and 3" PVC, ABS or CPVC Schedule 40 piping and fittings

are acceptable materials for the vent system on all models.

• It cannot be connected to existing vent piping or chimney.

• It must terminate horizontally to the outdoors.

NOTE: See pages 22 and 23 for vertical venting through a roof.