Troubleshooting software downloads – Cisco 700 User Manual

Page 93

Advertising
background image

Terminal Communications B-7

Troubleshooting Software Downloads

If the download was not successful, use Table B-3, which shows symptoms and possible
solutions.

A combination of blinking LEDs indicates a software download problem. An error code is
also displayed on the terminal.

Table B-4 lists the combination of blinking LEDs that indicate an error, along with the error
code and a description of the error.

Table B-3

Software Download Command Troubleshooting

Symptom

Probable Cause and Solution

Download takes
significantly longer than
the approximate time listed
in Table B-2.

The terminal emulation program interline and intercharacter delays
are not set to zero. If the load was successful, no further action is
necessary. If the load was terminated prematurely, reset the interline
and intercharacter delays to zero, and reload the software.

The terminal displays
unrecognizable text after
the download is completed.

The terminal has not been reset to 9600 baud. Reset the terminal
any time after loading the new software. After changing the
terminal baud rate, press Return to display the prompt (>).

Two or more LEDs are
blinking.

Incorrect configuration of the PC COM port or a defective console
cable. Press Esc and try to load the software again.

Table B-4

LED Error Messages—Software Download

Blinking LED

Error Code

Description of Error

Line

CH 2

E-1

A framing, parity, or overflow error occurred during
software download, usually because of an incorrect data rate
or configuration port setting. Check the data rate and
configuration port settings.

CH 1

E-2

A colon was not at the beginning of a line in the new
software image file. Either the software image file is
corrupted or some characters were entered before the
download started. Start the software load process again. If
the same error occurs, replace the software image file.

Advertising