DeviceMaster UP PROFINET IO Installation Quick Start

2000484 Rev. E ­ 1


PROFINET IO Installation Quick Start

This document is intended to provide you with a way to locate software and installation documentation for the 

DeviceMaster UP. 
In addition, use this document to quickly configure:

Read‐only devices such as barcode scanners and some RFID readers

Read/write devices such as printers and some weigh scales

B

LUE

 

CAPS

 link to external documents, which function if reading this document from the web/ftp site or CD. 

Red

underlined links go to the web site and 

blue

, underlined links jump within the document and provide a page number.

Installation Overview

Use the following steps to install the DeviceMaster UP.
1.

I

NSTALL

 

THE

 

HARDWARE

.

2. Install PortVision DX from the CD or download and install 

the latest version.

3.

C

ONFIGURE

 

THE

 D

EVICE

M

ASTER

 UP

 network settings using 

PortVision DX.

4. Depending on the DeviceMaster UP model, do the following:

Models without PROFINET IO loaded, you must install the 

software assembly (.msi) from the CD or download and 

install the latest file, which contains the PROFINET IO 

firmware, GSDML, and bitmap for Step7. By default, these 

files are saved in c:\Comtrol\ProfinetIO and are need for 

Step 5

Models with PROFINET IO loaded on the DeviceMaster UP, you should check to see if a later version of PROFINET 

IO is available for installation. Check the PROFINET IO version in PortVision DX against the web site to see if a 

later version is available. Typically, you should download and install the latest .msi file and upload the latest 

version, which may include updates or enhancements.

Note: Models that have PROFINET IO loaded on the DeviceMaster UP are identified in PortVision DX and the 

DeviceMaster UP is labeled accordingly.

5.

I

F

 

NECESSARY

UPLOAD

 the PROFINET IO firmware into the DeviceMaster UP using PortVision DX.

Note: Do not perform Step 6 before Steps 1 through 5.
6. Configure the serial or Ethernet TCP/IP socket port characteristics using the DeviceMaster UP embedded web page 

(Server Configuration). 
If you have Read­only or read/write devices, you can use the appropriate procedures for your device, which are 

located in this document:

Read‐only devices (barcode scanners and some RFID readers), go to 

Configuring Read­Only Serial Devices

 on 

Page 2 or 

Configuring Read­Only Ethernet TCP/IP Devices

 on Page 4.

Read/write devices (printers and some weigh scales), first perform the appropriate procedure for a read‐only 

device and then go t

Configuring Read/Write Devices

 on Page 6.

Software and Documentation

Web

DeviceMaster UP Hardware Installation 

and Configuration Guide

PortVision DX

PROFINET IO firmware

DeviceMaster UP Filtering and Data 

Extraction Reference Guide