DeviceMaster UP PROFINET IO Installation Quick Start

2000484 Rev. E ­ 3

Configuring Read­Only Serial Devices

4. Set up the serial port configuration. (ModeBaud rate, etc.) 

Note: Refer to your serial device's User Manual for these settings.

5. If desired, uncheck Discard Rx Packets with Errors.
6. Set up the Serial Packet 

Identification
a. Set STX (Start of

transmission) Rx Detect

 in 

decimal format. 

b. Set ETX (End of

transmission) Rx Detect

 in 

decimal format. 

c. Set the PLC

®

 specific Strip

Rx STX/ETX Chars

 

setting if you do not wish to 

receive the STX/ETX bytes 

in the received data packet.

Note: Please refer to your 

device's User Manual for the Start and End of Transmission byte(s) settings.  You may also be able to use the 

Serial Interface Logs page to determine these settings.

7. Set the Filtering/Data Extraction Configuration:

If no filtering/data extraction is required, leave all filtering/data extraction settings to defaults.

If filtering/data extraction is required, go to 

Filtering/Data Extraction Configuration (Patent Pending)

 on Page 

11.

8. Set the Application TCP Connection Configuration.

If no application socket interface is required, leave all application socket interface settings at defaults and the 
Application Enable

 option unselected.

If an application socket interface is required, go to 

Application Socket Configuration (Patent Pending)

 on Page 16.

9. Verify Reset Port and Save in Flash are selected and click on Submit.
If all is set up correctly, the DeviceMaster UP will place the data packets into the location specified in Step7. See the 

example program in section 

Example Programs

 on Page 8 or Siemens Step7 documentation for more information on how 

this is done. The first WORD is an integer received representing the sequence number. This is incremented with each 

new data packet. The next WORD indicate the length, which is the number of bytes of data received. The rest is data. For 

example, the first “packet” received from the DeviceMaster UP might have a sequence number of 1 (0x0001), a length of 

7 bytes (0x0007) and seven data bytes (for instance ABCDEFG, or {0x41, 0x42, 0x43, 0x44, 0x45, 0x46, 0x47} in ASCII 

text).
Note: If the buffer is not large enough to hold the entire packet the data will be truncated (i.e. only the

beginning part of the packet will be written to the controller). For example, if we were using a 4 BYTE
output buffer only ABCD or {0x41, 0x42, 0x43, 0x44} would appear in the buffer. The other BYTEs
would be ignored.