DeviceMaster UP PROFINET IO Installation Quick Start

Application Socket Configuration (Patent Pending)

Application Socket Configuration (Patent Pending)

Access the Application TCP Connection Configuration section corresponding to the desired serial or socket port:
1. Select Enable.
2. If your Ethernet TCP/IP application requires 

another device to connect to it, configure the 

socket port on the DeviceMaster UP to Connect 

mode:
a. Leave Listen unselected.
b. Set Connect To Mode to Connect-Always.
c. Set the Connect Port to the socket port 

number of your Ethernet application.

d. Set the Connect IP Address to the IP 

address of your Ethernet application.

e. Set Disconnect Mode to Never.

3. If your Ethernet TCP/IP application is 

configured to connect to another device, 

configure the socket port on the DeviceMaster 

UP to Listen mode: 
a. Select Listen.
b. Use the default Listen Port on the 

DeviceMaster UP of 8xxx or designate your 

own.

c. Set Connect To Mode to Never.
d. Set Disconnect Mode to Never.
e. Configure your Ethernet application to 

connect to the DeviceMaster UP at the DeviceMaster UP IP address and Listen Port.

4. If you do not know if your application 

will connect to another Ethernet 

device, but do know your application’s 

socket port and IP address, you can do 

the following to enable both the Listen 

and Connect modes:
a. Select Listen.
b. Use the default Listen Port on the 

DeviceMaster UP of 8xxx or 

designate your own.

c. Set Connect To Mode to Connect-

Always

.

d. Set the Connect Port to the socket 

port number of your Ethernet 

application.

e. Set the Connect IP Address to the IP address of your Ethernet application.
f.

Set Disconnect Mode to Never.

g. Optionally configure your Ethernet application to connect to the DeviceMaster UP at the DeviceMaster UP IP 

address and Listen Port.