Rfid (epcglobal formats) – Comtrol PROFINET IO User Manual

Page 12

Advertising
background image

12 ­ 2000484 Rev. E

DeviceMaster UP PROFINET IO Installation Quick Start

RFID (EPCglobal Formats)

RFID (EPCglobal Formats)

Use the following procedure to configure PLC filtering and data extraction properties for RFID devices using an EPCglobal 

format.
1. Set any or all of the To PLC Filter Options (RFID Only) filtering options.
2. Set any or all of the To PLC Filter Options (RFID/Barcode) filtering options.

Note: You must select at least one filtering option for filtering/data extraction to function.

3. If Antenna Grouping is desired, set RFID Antenna Grouping option to reflect your antenna configuration. The 

antenna grouping allows you to treat a subset of the antennas on a RFID reader as a single RFID reader. See the 

DeviceMaster UP Filtering and Data Extraction Reference Guide

 for more detail.

4. Set the RFID Reader Interface Type to that of your RFID Reader configuration. If your RFID Reader is not listed, 

refer to the 

DeviceMaster UP Filtering and Data Extraction Reference Guide

 for the supported RFID reader interfaces. 

If your RFID reader format matches one of the listed formats, then set the RFID Reader Interface Type to that 

format.

5. Set the Filter Age Time to how long after the last read you want an entry to be filtered. In other words, after receiving 

a tag that matches the filtering criteria, no other tags that match the same criteria will be sent until the amount of 

time specified in the Filter Age Time has expired.

6. If you want the DeviceMaster UP to discard any non‐RFID tag messages, set the Discard Unrecognized Data to either 

To-PLC

 or To-PLC/Application

Refer to the 

DeviceMaster UP Filtering and Data Extraction Reference Guide

 for more information.

To PLC RFID Data Format
When the PLC interface is operating in RFID filtering mode, all data sent to the PLC will be in the following format:

Field

Data Type

Description

Produced data
sequence number

WORD

Values = 0‐65535 (FFFF Hex)

Sequence number that is incremented with each new 

message. 

Length of RFID
message

WORD

Values = 20‐148

Length in bytes of following data. 

Company Code

DWORD[2]

Company Code extracted from tag data. Depending on 

encoding scheme, this field may include Company 

Prefixes, Company Prefix Indexes, or Government 

Managed Identifier.

Product/Location
Code

DWORD[2]

Product Code extracted from tag data. Depending on 

encoding scheme, this field may include the Item 

Reference, Location Reference, Asset Reference, 

Object Class, or be set to zero. 

Serial Number

DWORD[2]

Serial Number extracted from tag data. Depending on 

the encoding scheme, this field may include the Serial 

Number or Individual Asset Reference.

Encoding Scheme

WORD

Encoding Scheme from tag data.

Filtering Value

WORD

Filtering value from tag data.

Antenna Number

WORD

Antenna number on RFID reader/scanner.

Tag Data Length

WORD

Length of RFID tag string in bytes.

Tag Data

BYTE[128]

Tag data string (variable length field). May also include 

non‐tag messages, which can optionally be sent to the 

PLC and/or application.

Advertising