Motronic trigger, Ra4 wiring details – Haltech E6A User Manual

Page 116

Advertising
background image



116

Motronic Trigger

The Reluctor Adaptor, (RA4) is used for Motronic trigger wheels only. There are two
channels in the RA4, the primary and secondary.


RA4 Wiring Details


INPUT PLUG OUTPUT PLUG

Pin

Colour Wire

Function

Pin

Colour Wire

Function

A

BLUE

Primary Trigger (-)

A

BLACK

Ground

B

WHITE

Primary Trigger (+)

B

RED

+12 Volts

C

GREEN

Secondary Trigger (+)

C

YELLOW

Primary Trig

D

GREY

Secondary Trigger (-)

D

BROWN

Secondary Trig


The Motronic magnetic sensor has two wires, one positive (+), and the other negative (-), The
wires are sometimes marked as such, but more often they are not. It is very important that the
positive wire goes to the input pin B and negative wire goes to the input pin A. If you can not
determine which wire is positive or negative from marking or wire colour, then it would be
necessary to check the signal going into the RA4 using an oscilloscope.

A Motronic wheel more than often has 60 teeth (some are more or less), among them there are
two missing teeth which will often give a larger signal. The input to the RA4 must first go
positive(+), this arms the circuit in the RA4. When the signal rises about 50 mV, the RA4 will
generate a falling edge and when the signal crosses zero volt, the RA4 will generate a rising
edge. The larger pulse in the output of the RA4 for the missing teeth is recognised by the
Haltech ECU as the home position.

NOTE: In the IGNITION SETUP page Trigger Edge should be set to FALLING.