Port Name

Connector

Function

1~4

Alarm Input Port
1~4

I/O Port

 Alarm input channel amount is 4
 When your alarm input device is using

external power, please make sure the
device and the NVS have the same
ground.

Ground end

Alarm input ground end.

NO

Alarm Output
Port1

Output alarm signal to the alarm device.
Please make sure there is power to the
external alarm device.

NO:Normal open alarm output port.

C:Alarm output public end.

C

A

RS485 Port

RS485_A port. It is the cable A. You can
connect to the control devices such as speed
dome PTZ.

B

RS485_B.It is the cable B. You can connect
to the control devices such as speed dome
PTZ.

ANT

Antenna Port

To connect wireless antenna in order to
receive 3G wireless signal

Power input port

Input 12V DC

Power Button

Power on/off button.

When connect the Ethernet port, please use crossover cable to connect the PC and use the