Ktd-400 configuration – Interlogix KTD-400 User Manual

Page 10

Advertising
background image

KTD-400 Controller Keypad

User Manual

6

KTD-400 configuration

After you install and power up your KTD-400 keypad, you will need to configure it to operate within your
systems. You can also use the KTD-400 to configure other components in the Digiplex system. (See

System

component configuration

on page 10.)

The KTD-400 offers many programming choices that identify how it will function in the system. A separate
code is used to access the menus. For new installations, follow the programming steps in the order they are
presented. If you need to change any programmed data at a later date, enter the appropriate programming
mode and use the designated keys to advance the menu associated with that data.

System size (see Figure 11 on page 7)

Camera site access (see Figure 12 on page 7)

Monitor access (see Figure 13 on page 8)

Multiplexer enable and select (see Figure 14 on page 8)

Multiplexer view display (see Figure 15 on page 8)

VCR enabled (see Figure 16 on page 9)

Maximum presets (see Figure 17 on page 9)

Monitor offset (see Figure 18 on page 9)

When you supply power to the unit, the LCD will momentarily display a limited amount of configuration
information on the unit (Figure 7).

Figure 7. Programming display

After a few seconds, the normal operating display menu (Figure 8 on page 6) will appear.

To configure the KTD-400, do the following:.

1. In the normal operating display (Figure 8),

enter programming mode by pressing and
holding the Set key until you see the display
in Figure 9.

Figure 8. Normal operating display

2. At the code entry display (Figure 9), enter

the access code 5, 7, 9, Seq.

Figure 9. Code entry display

Largest Largest Largest Largest Monitor Key

camera monitor multiplexer VCR offset layout

Revision number

KTD-400 DDMMYY
255 64 64 64 00 0

CAMERA 000
MONITOR 01

CAMERA 000

(CODE)

MONITOR 01

(----)