KTD-400 Controller Keypad

User Manual

18

Camera sequencing

To place a monitor in the sequence mode, select the monitor and press Seq. The display shown in Figure 37
will appear in the keypad’s display window.

Figure 37. Sequence selection

Use 1 through 4 to enter the desired sequence tour.

Setting electronic autopan limits for domes

To set the electronic autopan limits on dome receivers, first position the dome at the limit. While holding down
the Zoom in and Zoom out keys, press the arrow keys in the direction of the limit being set. For example, to
set the left limit, move the dome to the position of the desired left limit. While holding down the Zoom in and
Zoom out keys, press the left arrow key.

Video alarms

To place a monitor in or remove it from the alarm mode, select the monitor and press Alarm. Each time you
press Alarm, the monitor toggles in and out of alarm mode. When a monitor is in alarm mode, an A appears on
the monitor screen (Figure 38). In this mode the monitor will automatically call alarmed sites.

Figure 38. Monitor screen with alarm mode enabled

A monitor will only respond to alarms if it is in alarm mode. A manual video call will take a monitor out of
alarm mode.

Clearing alarms

In a Digiplex system, alarmed sites can be programmed to remain on the monitor screen indefinitely, and must
be cleared by the operator. To clear the alarm, press Clear and use 0 through 9 to enter the site number. For
example, to clear alarm site 22, press Clear, 0, 2, 2.

ENTER SEQUENCE
NUMBER? - (1, 2, 3, 4)